HPM24 - 24 inch Master 

HPM30 - 30 inch Master

Available in Oscillating & Non-Oscillating  

 

Several years of research and development in the area of heat stress has produced "Evolution Series"- the Ultimate High-Pressure Misting Fan. This new cooling system can reduce the ambient air temperature by as much as 30 degrees, providing the ultimate of coolness without wetness.
At the heart of the Evolution system is a specially designed high-quality high-pressure pump that provides 800-1000 PSI. The Evolution exceeds the demands and requirements to be used in the harshest environments possible. When designing a system, we focus on low maintenance, long life span and strive for a customer friendly final product.

This misting system also allows for two satellite misting fans attached with quick connects with a high-pressure line to the pump. The Evolution is built with only he best components while incorporating and a state of the art filtration system. Cool Draft Scientific designed the Evolution series using high-tech 3D CAD engineering software, years of experience and customer feedback.

 

Rentals Available

 

 

HIGH PRESSURE COOLS WITHOUT WETNESS

We Use The Best Pumps Available

CAT PUMPS has become the world leader of industrial, reciprocating, high-pressure, triplex plunger pumps. Our high quality components, exceptionally long lasting seals and field-proven dependability have made them the pump of choice where continuous-duty performance and low-maintenance are priorities.  Cat Pumps

Operating System:

  • 120 volt, 11 amp, 1/2 hp motor and CAT-brand Triplex Plunger Pump that delivers 1/2 gallon of water per minute at 1000 psi. Pump has onboard, adjustable, Regulating Unloader for Pressure Control and Pump Protection; Oil Level Sight Glass and Bypass System for variable nozzle set-ups (more or less Mist with up to 24 .008" Anti-drip Nozzles).

  • Pressure Gauge installed at Regulator for easy pressure adjustment.

  • 5 Micron Canister Water Filter.

  • Automatic Low Water Pressure Shut-off.

  • Female Coupler for standard 5/8" water hose (Water Input Supply).

  • Two Male Quick Disconnects for water supply to two Additional Satellite Fans.

  • 3-postion DPDT switch (Fan Only, Fan and Pump, Off ).

  • GFCI Integral to cordset protects total system from leakage current.

  • Modular system components can be combined to construct a portable misting system using 24" or 30" oscillating or non-oscillating fans.

  • Fans can be operated with or without misting.

  • Pump Box Lid Hinged for easy access with 2 Stainless Steel Latches for Lock-down.

  • 6900 cfm

  • Black powder-coated cart with 10" all-terrain non-pneumatic wheels with wheel brake.

  • Permanently mounted pump box.

  • cord wraps and hose guide included on column assembly.

  • Adjustable column allows top of 30" fan to extend from 66" to 88".

  • Pump cart unit comes with 7' of 2500 psi rated hose; stainless steel closed-loop misting ring 8 nozzles (8 -.008" anti-drip nozzles and 4 plugs) for the master fan.

  • 1000 PSI Pump System Designed to run one master fan and up to two satellite fans.

 Evolution Satellite Fans:

 

 Our satellite fans connect to the master unit and can be positioned 30 feet in any direction from the master unit.

 The major benefit of a satellite fan is the addition of a high pressure fan for nearly 1/3 the price of a master. Also, the satellites allow you to cool more areas using just one water source.695.

 

24" Satellites & 30"Satellites Available

HPSAT24

HPSAT30

 

Shown here is the back of a master

 fan and the satellite connectors.

Permanent Mount High Pressure Fans

 Our high pressure fans can be mounted on any surface to provide a permanent structure with misting.

 Our pump will support three fans at any distance.

 This system can be used with our 24" or 30" fans. Great for outdoor patios, restaurants, outdoor shade structures, horse stables, poolside and more...

 Call for a free design layout and technical assistance.

 

More High Pressure Applications:

Military Applications
Our high pressure industrial misting systems help solve cooling problems in very hostile and acidic environments. Our military clients use our misting systems in very dry environments much like the ones found in the Middle East and Asia. Our cooling systems help the military not only cool the troops on base, but also are critical in cooling equipment helping keep the equipment operating effectively and efficiently in very hostile environments.

Factory and Warehouse Applications
In large industrial factories and warehouses our misting systems can be ceiling suspended or wall mounted. Any number of our misting fans can be served high pressure water by one central pump module connected to the multiple fans by a high pressure manifold hose. A secondary benefit is dusty environments will have the air cleaned by the fog from the misting fans.

Unsurpassed dust suppression can be achieved through the proper use of ultra fine fog. Independent university studies have shown the key to successful dust suppression is the controlled application of water droplets no larger than 10 microns, produced under high pressure. Dust particles are trapped, without ever wetting materials or the ground.

Refineries
Refineries have huge open spaces where workers are constantly working in hot environments. Cool Draft steps in and creates ‘cool zones’ for those workers. Refinery workers are able to step in our cool areas to help lower their body temperatures dramatically. Instead of being forced to go inside every few minutes to cool off our systems allow the worker to be on the specific job site for prolonged periods of time thus increasing productivity while reducing safety concerns at the same time.

Process Cooling
Our systems are used to produce dramatic results reducing cooling times for castings or other hot products. The improved cooling time is a result of enhanced heat transfer, achieved due to fog's evaporative cooling effect and boundary layer disturbances. We are able to saturate the air stream with air aspirated fog directed at the hot surfaces. Typically, the process cooling is delivered through a controlled staging process. These systems are custom designed to specific needs and application.

Livestock
During hot summer months it is absolutely vital to keep animals cool and safe from the heat. The combination of humidity and heat may not allow livestock to shed their extreme body heat. Cool Draft uses a variety of systems to solve these problems.

 

 

Mobile 1       Cool Draft Blue        Cool Draft Cart         Evolution High Pressure  
Copyright © 2004 Cool Draft Scientific. All rights reserved.
Last modified: 03/22/09.